Power management fails due to maas-power failure

Bug #2042429 reported by Anton Troyanov
10
This bug affects 2 people
Affects Status Importance Assigned to Milestone
MAAS
Fix Released
High
Anton Troyanov

Bug Description

Nov 01 08:01:29 maas-system-maas maas-agent[10576]: 8:01AM ERR error executing power command error="exit status 1" ActivityID=5 ActivityType=power Attempt=14 Namespace=default RunID=20f124e6-197b-4d4a-8c4f-b88fa9d3e20a TaskQueue=vlan-2 WorkerID=rqgh7t:10576:vlan-2 WorkflowID=power:power_on:mmqch6:511535.348032266 WorkflowType=power_on stdout=

While digging further with @ bjornt we discovered that command line arguments are not quoted correctly

Related branches

Changed in maas:
milestone: none → 3.5.0
status: New → Triaged
assignee: nobody → Anton Troyanov (troyanov)
importance: Undecided → High
Changed in maas:
status: Triaged → Fix Committed
Changed in maas:
status: Fix Committed → In Progress
Changed in maas:
status: In Progress → Fix Committed
Changed in maas:
milestone: 3.5.0 → 3.5.0-beta1
Changed in maas:
status: Fix Committed → Fix Released