Power management fails due to maas-power failure
Bug #2042429 reported by
Anton Troyanov
This bug affects 2 people
Affects | Status | Importance | Assigned to | Milestone | |
---|---|---|---|---|---|
MAAS |
Fix Released
|
High
|
Anton Troyanov |
Bug Description
Nov 01 08:01:29 maas-system-maas maas-agent[10576]: 8:01AM ERR error executing power command error="exit status 1" ActivityID=5 ActivityType=power Attempt=14 Namespace=default RunID=20f124e6-
While digging further with @ bjornt we discovered that command line arguments are not quoted correctly
Related branches
~troyanov/maas:fix-2042429
Merged
into
maas:master
- Björn Tillenius: Approve
- MAAS Lander: Approve
-
Diff: 393 lines (+111/-65)6 files modifiedsrc/maasagent/internal/workflow/deploy.go (+2/-4)
src/maasagent/internal/workflow/deployed.go (+6/-7)
src/maasagent/internal/workflow/ephemeral.go (+8/-10)
src/maasagent/internal/workflow/log/tag/tags.go (+16/-12)
src/maasagent/internal/workflow/power.go (+34/-32)
src/maasagent/internal/workflow/power_test.go (+45/-0)
~bjornt/maas:maas-power-multiple-choice
Merged
into
maas:master
- MAAS Lander: Approve
- Anton Troyanov: Approve
-
Diff: 76 lines (+21/-1)2 files modifiedsrc/provisioningserver/power_driver_command.py (+4/-0)
src/provisioningserver/tests/test_power_driver_command.py (+17/-1)
Changed in maas: | |
milestone: | none → 3.5.0 |
status: | New → Triaged |
assignee: | nobody → Anton Troyanov (troyanov) |
importance: | Undecided → High |
Changed in maas: | |
status: | Triaged → Fix Committed |
Changed in maas: | |
status: | Fix Committed → In Progress |
Changed in maas: | |
status: | In Progress → Fix Committed |
Changed in maas: | |
milestone: | 3.5.0 → 3.5.0-beta1 |
Changed in maas: | |
status: | Fix Committed → Fix Released |