Update notify websocket message not sent when changing machine power parameters
Bug #1944847 reported by
Caleb Ellis
This bug affects 1 person
Affects | Status | Importance | Assigned to | Milestone | |
---|---|---|---|---|---|
MAAS |
Fix Released
|
High
|
Alberto Donato |
Bug Description
When changing the power parameters of a machine via the UI, we don't get back a machine update notify message with the updated machine object. This is not the case when updating other machine values, like power_type, zone etc.
This has only been noticeable since certificates could be generated. Since the user has no input on the actual value of the certificate and key it's not shown in the form once generated, whereas every other power parameter is explicitly given by the user.
Related branches
~ack/maas:1944847-machine-bmc-update-notification
Merged
into
maas:master
- Björn Tillenius: Approve
- MAAS Lander: Approve
-
Diff: 246 lines (+123/-16)3 files modifiedsrc/maasserver/triggers/tests/test_init.py (+17/-16)
src/maasserver/triggers/tests/test_websocket_listener.py (+67/-0)
src/maasserver/triggers/websocket.py (+39/-0)
Changed in maas: | |
status: | New → Triaged |
importance: | Undecided → High |
milestone: | none → next |
Changed in maas: | |
assignee: | nobody → Alberto Donato (ack) |
Changed in maas: | |
status: | Triaged → In Progress |
Changed in maas: | |
status: | In Progress → Fix Committed |
Changed in maas: | |
milestone: | next → 3.1.0-beta2 |
Changed in maas: | |
status: | Fix Committed → Fix Released |
To post a comment you must log in.