net: Make sysconfig renderer compatible with Network Manager.
The 'sysconfig' renderer is activated if, and only if, there's ifup and
ifdown commands present in its search dictonary or the network-scripts
configuration files are found. This patch adds a check for Network-
Manager configuration file as well.
This solution is based on the use of the plugin 'ifcfg-rh' present in
Network-Manager and is designed to support Fedora 29 or other
distributions that also replaced network-scripts by Network-Manager.
ad170db...
by
Marlin Cremers <email address hidden>
cc_set_passwords: Fix regex when parsing hashed passwords
Correct invalid regex to match hashes starting with the following:
- $1, $2a, $2y, $5 or $6
net: Wait for dhclient to daemonize before reading lease file
cloud-init uses dhclient to fetch the DHCP lease so it can extract
DHCP options. dhclient creates the leasefile, then writes to it;
simply waiting for the leasefile to appear creates a race between
dhclient and cloud-init. Instead, wait for dhclient to be parented by
init. At that point, we know it has written to the leasefile, so it's
safe to copy the file and kill the process.
cloud-init creates a temporary directory in which to execute dhclient,
and deletes that directory after it has killed the process. If
cloud-init abandons waiting for dhclient to daemonize, it will still
attempt to delete the temporary directory, but will not report an
exception should that attempt fail.
[Azure] Increase retries when talking to Wireserver during metadata walk
Testing startup of large numbers of VMs (of varying distros) in Azure
shows that 3 retries results in a small percentage of failed VMs.
Increasing that by a few dramatically decreases the occurrence of
provisioning timeout errors. The initial choice of "3 retries" was
uninformed by heavy testing. Also, the alternate provisioning
mechanism for Azure (waagent) retries the Wireserver crawl without
limit. 10 retries seems a more reasonable choice.
The change to datasources.rst here is obvious typo fix.
The change to azure is to reduce the two 'Customization' sections
to a single and clean up some other duplicate text.
OVF: simplify expected return values of transport functions.
Transport functions (transport_iso9660 and transport_vmware_guestinfo)
would return a tuple of 3 values, but only the first was ever used
outside of test. The other values (device and filename) were just
ignored.
This just simplifies the transport functions to now return content
(in string format) or None indicating that the transport was not found.
Vmware: Add support for the com.vmware.guestInfo OVF transport.
This adds support for reading OVF information over the
'com.vmware.guestInfo' tranport. The current implementation requires
vmware-rpctool be installed in the system.