PTH drill map (.pho file) overwritten by NPTH drill map
Bug #1172892 reported by
Chris Elliott
This bug affects 3 people
Affects | Status | Importance | Assigned to | Milestone | |
---|---|---|---|---|---|
KiCad |
Fix Released
|
Undecided
|
Unassigned |
Bug Description
Discovered on build 2013-04-19 BZR 4011.
When generating drill maps on a board with both plated and npt holes, I can see in the status window that both files are generated with the same name (*-drl.pho). The second generated drill map (in my case the NPTH map) overwrites the first generated drill map file.
Looking back at previous gerber outputs generated on build 2012-01-19 BZR 3256 I can find both the *-drl.pho and *-NPTH-drl.pho files. This bug crept in somewhere between BZR 3256 and BZR 4011.
Edit: Removed extraneous (and possibly confusing) word "only" from 4th sentence.
description: | updated |
Changed in kicad: | |
status: | Incomplete → Fix Committed |
Changed in kicad: | |
status: | Fix Committed → Fix Released |
To post a comment you must log in.
I do not have this issue:
Both *-drl.pho and *-NPTH-drl.pho files are created.
Please, be sure you have NPT holes.
The Dialog shows the number of PTH and NPTH.
Are 2 drill files created ?